MIL-C-80036C
a n d adjustment.
T h e equipment shall include r e g u l a t i o n o f p r e h e a t f u e l ,
preheat oxygen, a n d the cutting oxygen. An i n d i v i d u a l s o l e n o i d v a l v e t o
c o n t r o l the cutting oxygen shall be furnished for each torch.
A system for
c o n t r o l l i n g preheat and fast piercing starts shall be furnished.
Flow of
gases shall be automatically controlled by solenoid valves which shall
i m m e d i a t e l y close when the master control switch is turned to the off posi-
tion.
R e g u l a t i o n and manifolding shall be of sufficient capacity to accom-
m o d a t e the specified number of torches.
T h e manifold shall have capped
outlets for future installation of additional torches in accordance with
r e q u i r e m e n t s listed in table I. All other associated gas control equipment,
i n c l u d i n g hoses and fittings necessary for internal machine connection and
o p e r a t i o n , s h a l l be included. All components shall be mounted and protected
to withstand the operating conditions encountered when the machine is oper-
ated at maximum rated load and speed.
When hose lengths exceed 7 feet,
s u i t a b l e means shall be provided for relieving the weight and preventing
entanglement and chafing of the hoses to each torch.
T e m p l a t e table.
3.4.11
An independent, m o v e a b l e template table of
d i m e n s i o n s necessary to meet the requirements in this specification shall be
f u r n i s h e d with the size machine specified.
W h e n specified (see 6.2.1),
a d d i t i o n a l sections of template table shall be furnished.
T h e table shall
m o v e on a set of rails, with height and level adjustment provided.
Means
s h a l l be provided to quickly and easily position the table in any desired
p o s i t i o n along its track.
3.4.12 Electrical System.
U n l e s s otherwise specified (see 6.2.1), the
e l e c t r i c a l system shall conform to ANSI/NFPA 79. Unless otherwise specified
( s e e 6.2.1), electrical input power shall be 115 volt, single phase, 60 Hz,
AC.
3.4.13 Motors.
M o t o r s shall be rated for continuous duty and shall
h a v e ball or roller bearings of the sealed and permanently lubricated type.
All motors not mounted in enclosed compartments shall be of the totally en-
c l o s e d type. Motor horsepower and speed shall be adequate to meet maximum
o p e r a t i n g conditions.
3.4.14
S o l i d state components,
Solid state design shall be used
t h r o u g h o u t for electronic components,
3.5 Size and capacity.
U n l e s s otherwise specified (see 6.2.1), the
s i z e and capacities o f the machine shall be not less than those specified in
t a b l e I for the machine size specified.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business